One-Step RT-PCR Kit (Probe-Based)
Fluorescent probe
High sensitivity and specificity
Universal compatibility
This website uses cookies We use cookies to personalise content and ads, provide social media features and analyse our traffic. We share information about how you use our website with our social media, advertising and analytics partners. Partners may combine this information with other information you provide to them or that they obtain as a result of your use of their services.
For Research Use Only.

Figure: Amplification of human GAPDH gene target with 2X HoTaq Real-time PCR Kit. Amplification curves are shown for ten fold dilutions of 0.0002pM to 20pM of plasmid. Inset shows the standard curve data.
Description:
This is a high performance real-time PCR reagent. It utilizes MCLAB's proprietary quantitative PCR technology.
Advantages:
2x HoTaq PCR Reaction Mix products are superior in amplifying difficult templates comparing with similar products from other suppliers.
- This is the amplification of GPIIB gene (70% G+C) .
- 10 ~ 10K copies from 30pg human genomic DNA have been detected.
Application:
Probe based quantitative PCR: including DNA quantification, 2-step RT PCR, SNP analysis, etc.
Primer and probe design:
1. To achieve the best performance, appropriate software, such as ABI Primer ExpressTM, should be used to design primers with 50°C~65°C annealing temperature and 68°C~70°C for probes with 17~30 nucleotides in length
2. Amplicon size should be small, <150bp
3. Avoid secondary structures in primers and probes
4. Avoid more than 3 consecutive Gs in primers and probes
5. Primers should not have complementary 3' -ends
6. 17 ~ 30 nucleotides in length
Recommended Reaction Conditions: :
95°C, 10 minutes. -> (95°C, 5 seconds. -> 60°C, 30 seconds.) for 50 cycles.
Recommended Storage Condition:-20°C
Notes:
To achieve accurate quantification, it is highly recommended to do replicates and to reduce pipetting errors.
Reference:
1. Holland, P. M., Abramson, R. D., Watson, R., and Gelfand,
2. D. H. 1991. Proceedings of the National Academy of Sciences USA 88:7276-7280.
3. Livak, K. J., Flood, S. J. A., Marmaro, J., Giusti, W., and Deetz, K. 1995. PCR Methods and Applications 4:357-362.
4. Lee, L. G., Connell, C. R., and Bloch, W. 1993 Nucleic AcidsResearch 21:3761-3766.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Fluorescent probe
High sensitivity and specificity
Universal compatibility
The MCLAB's HoTaq™ SYBR Green One-Step RT-PCR Kit allows researchers to perform SYBR Green based RT-qPCR in a single step within a single tube.
ROX Free, for Real-time PCR Machines BioRad iCycler MiniOpticon, Opticon 2, Chromo4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo4; Corbett Roto-gene 3000, 6000, 4x1.25ml
Low level of ROX, for Real-time PCR Machines ABI 7500, Mx 3000P, Mx 3005P, 4x1.25ml
Fluorescent dye
High sensitivity and specificity
Universal compatibility
Low level of ROX, for Real-time PCR Machines ABI 7500, Mx 3000P, Mx 3005P, 4x1.25ml
Regular level of ROX, for Real-time PCR Machines ABI 7000, 7300, 7700, 7900, 4x1.25ml
check_circle
check_circle