2X HoTaq™ qPCR Kit For TaqMan®
ROX Free, for Real-time PCR Machines BioRad iCycler MiniOpticon, Opticon 2, Chromo4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo4; Corbett Roto-gene 3000, 6000, 4x1.25ml
This website uses cookies We use cookies to personalise content and ads, provide social media features and analyse our traffic. We share information about how you use our website with our social media, advertising and analytics partners. Partners may combine this information with other information you provide to them or that they obtain as a result of your use of their services.
Sybr green dye based 4x1.25ml for 200 reactions. Designed for all kinds of real-time PCR machines.
| Rox Reference Dye | Instrument | Catalog No. |
| No Rox | BioRad iCycler MiniOpticon, Opticon 2, Chromo 4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo 4; Corbett Rotogene 3000, 6000 | HSM400RF |
| Low Rox | ABI® 7500 qPCR Systems, ViiA™ 7, QuantStudio™ 12K Flex, Agilent Mx3000P™ Mx3005P™ and Mx4000™ | HSM400LR |
| Regular Rox | ABI® PRISM® 7000, 7700, 7900HT, ABI® 7300 qPCR Systems, GeneAmp® 5700, StepOne™, and the StepOnePlus™ | HSM400 |
For Research Use Only.

Figure: Amplification of human GAPDH gene target with 2X HotSybr Real-time PCR Kit. Amplification curves are shown for ten fold dilutions of 0.0002pM to 20pM of plasmid. Insets show the dissociation profile and the standard curve data.
Description:
This is a high performance real-time PCR reagent. It utilizes MCLAB's proprietary quantitative PCR technology.
Advantages:
2x HotSybr PCR Reaction Mix products cut the total reaction time down to half.
- Normally the total reaction time is 4350 seconds: 95°C, 10 minutes => (95°C, 15 seconds => 60°C, 60 seconds) x 50
- For MCLAB's 2x HotSybr PCR Reaction Mix, the total reaction time is reduced to 2350 seconds: 95°C, 10 minutes => (95°C, 5 seconds => 60°C, 30 seconds) x 50
Application:
Sybr green dye based quantitative PCR: including DNA quantification, 2-step RT PCR, SNP analysis, etc.
Primer and probe design:
Appropriate software, such as ABI Primer ExpressTM, should be used.
Recommended Reaction Conditions:
95°C, 10 minutes -> (95°C, 5 seconds. -> 60°C, 30 seconds.) for 50 cycles -> melting curve.
Recommended Storage Conditions: -20°C
Notes:
To achieve accurate quantification, it is highly recommended to (1) do replicates; (2) reduce pipetting error; (3) primer concentration from 100nM to 300nM; (4) run melting curve following amplification cycles.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
ROX Free, for Real-time PCR Machines BioRad iCycler MiniOpticon, Opticon 2, Chromo4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo4; Corbett Roto-gene 3000, 6000, 4x1.25ml
Fluorescent probe
High sensitivity and specificity
Universal compatibility
The MCLAB's HoTaq™ SYBR Green One-Step RT-PCR Kit allows researchers to perform SYBR Green based RT-qPCR in a single step within a single tube.
Fluorescent dye
High sensitivity and specificity
Universal compatibility
Regular level of ROX, for Real-time PCR Machines ABI 7000, 7300, 7700, 7900, 4x1.25ml
Low level of ROX, for Real-time PCR Machines ABI 7500, Mx 3000P, Mx 3005P, 4x1.25ml
|
Regular level of ROX, 200 rnx, 4x1.25ml
|
check_circle