Read moreSybr green dye based 4x1.25ml for 200 reactions. Designed for all kinds of real-time PCR machines.
Rox Reference Dye | Instrument | Catalog No. |
No Rox | BioRad iCycler MiniOpticon, Opticon 2, Chromo 4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo 4; Corbett Rotogene 3000, 6000 | HSM400RF |
Low Rox | ABI® 7500 qPCR Systems, ViiA™ 7, QuantStudio™ 12K Flex, Agilent Mx3000P™ Mx3005P™ and Mx4000™ | HSM400LR |
Regular Rox | ABI® PRISM® 7000, 7700, 7900HT, ABI® 7300 qPCR Systems, GeneAmp® 5700, StepOne™, and the StepOnePlus™ | HSM400 |
For Research Use Only.
Figure: Amplification of human GAPDH gene target with 2X HotSybr Real-time PCR Kit. Amplification curves are shown for ten fold dilutions of 0.0002pM to 20pM of plasmid. Insets show the dissociation profile and the standard curve data.
Description:
This is a high performance real-time PCR reagent. It utilizes MCLAB's proprietary quantitative PCR technology.
Advantages:
2x HotSybr PCR Reaction Mix products cut the total reaction time down to half.
- Normally the total reaction time is 4350 seconds: 95°C, 10 minutes => (95°C, 15 seconds => 60°C, 60 seconds) x 50
- For MCLAB's 2x HotSybr PCR Reaction Mix, the total reaction time is reduced to 2350 seconds: 95°C, 10 minutes => (95°C, 5 seconds => 60°C, 30 seconds) x 50
Application:
Sybr green dye based quantitative PCR: including DNA quantification, 2-step RT PCR, SNP analysis, etc.
Primer and probe design:
Appropriate software, such as ABI Primer ExpressTM, should be used.
Recommended Reaction Conditions:
95°C, 10 minutes -> (95°C, 5 seconds. -> 60°C, 30 seconds.) for 50 cycles -> melting curve.
Recommended Storage Conditions: -20°C
Notes:
To achieve accurate quantification, it is highly recommended to (1) do replicates; (2) reduce pipetting error; (3) primer concentration from 100nM to 300nM; (4) run melting curve following amplification cycles.