https://www.carolinabiosystems.cz/626-thickbox_default/ida-agaroza-pro-his-znacene-rekombinantni-proteiny.jpg View full size

Catridge with IDA Agarose for His-tagged Recombinant Proteins

Contact us

Ni2+, Co2+, Cu2+, or Zn2+ charged iminodiacetic acid (IDA) coupled to Agarose CL-6B via a stable and uncharged long ether hydrophilic spacer arm, and offers high binding capacity and minimal non-specific binding.

Description

FastSep high performance resins and chromatography cartridges

Numerous ligand-metal ion combinations 
High affinity & high capacity 
Minimal non-specific binding & excellent purity 
Long spacer arms & minimal steric hindrance 
Low metal ion leaching & excellent stability 
Maintain high performance after multiple repeated use 

 

Application

For His-tagged protein purification 
Simply replace your existing IDA resin or cartridge, no optimization or protocol changes necessary 
Purification under native and denaturing conditions 
Suitable for small proteins, large protein complexes, and proteins with low expression rates 

 

Purification of His-tagged Recombinant Proteins

A his-tag, or polyhistidine tag, is a string of histidine residues at either the N or C terminus of a recombinant protein. Such a string can have 4 to 10 residues, with 6 being the most common a hexahistidine tag. Recombinant proteins can have more than one hexahistidine tag. 

In IMAC, metal ions are immobilized on a resin matrix using a chelating agent such as NTA or IDA. 

Ni2+, Co2+, Cu2+ and Zn2+are the most commonly used ions for his-tag purification of a recombinant protein. The his-tag has a high affinity for these metal ions and binds strongly to IMAC column, while most other proteins in the lysate will not bind to resin, or bind only weakly. The use of a his-tag and IMAC can therefore provide relatively pure recombinant protein directly from a crude lysate. 

 

How to choose different ligands and metal ions in IMAC?

NTA and IDA are the two most widely used ligands in IMAC. NTA is a tetravalent ligand with coordination number 4 and therefore stronger coordination of metal ions, while IDA is a trivalent ligand with coordination number 3. Generally, NTA gives higher binding specificity and lower metal ion leaching, while IDA shows more non-specific binding and increased metal ion leaching. IDA can have higher metal ion loading density and usually requires much lower imidazole concentration in eluent. 

For metal ions going from Co2+, Zn2+, Ni2+ to Cu2+, generally binding affinity increases while binding specificity decreases. Cu2+ has the highest affinity giving the highest protein recovery, but low specificity. Co2+ has the lowest affinity but highest specificity, reducing the amount of impurity proteins in eluate. Ni2+ is often most widely used because it provides a good balance between affinity and specificity. 


As many factors can affect the choice of optimal ligand-metal ion combination, the best approach is to try different combinations and let your proteins decide. FastSep(TM) high performance resins and cartridges offer numerous ligand-metal ion combinations to meet various purification needs. 
FastSep(TM) high performance resins and chromatography cartridges are based on highly cross-linked agarose 6% beads which have structural characteristics that result in superb physical strength, excellent flow properties, low backpressure, and an open pore structure. FastSep(TM) high performance resins and chromatography cartridges allow operation at very high flow rates, resulting in increased throughput and rapid column cleaning between chromatography runs.

 

Name

Cat#

Description

Ni-IDA Cartridge

NIIDA-CC1X5

5 x 1ml nickel-charged IDA cartridge

Ni-IDA Cartridge

NIIDA-CC5

1 x 5ml nickel-charged IDA cartridge

Ni-IDA Cartridge

NIIDA-CC5X5

5 x 5ml nickel-charged IDA cartridge

Co-IDA Cartridge

COIDA-CC1X5

5 x 1ml cobalt-charged IDA cartridge

Co-IDA Cartridge

COIDA-CC5

1 x 5ml cobalt-charged IDA cartridge

Co-IDA Cartridge

COIDA-CC5X5

5 x 5ml cobalt-charged IDA cartridge

Cu-IDA Cartridge

CUIDA-CC1X5

5 x 1ml copper-charged IDA cartridge

Cu-IDA Cartridge

CUIDA-CC5

1 x 5ml copper-charged IDA cartridge

Cu-IDA Cartridge

CUIDA-CC5X5

5 x 5ml copper-charged IDA cartridge

Zn-IDA Cartridge

ZNIDA-CC1X5

5 x 1ml zinc-charged IDA cartridge

Zn-IDA Cartridge

ZNIDA-CC5

1 x 5ml zinc-charged IDAcartridge

Zn-IDA Cartridge

ZNIDA-CC5X5

5 x 5ml zinc-charged IDA cartridge

  

Specification

Chromatography technique

Histidine-tagged protein purification

Matrix 

Highly cross-linked 6% beaded agarose

Active group

Ni2+, Co2+, Cu2+, or Zn2+ charged Iminodiacetic Acid (IDA)

Active group density

>40 umol/ml drained medium 

Binding capacity

>40 mg/ml drained medium

Spacer 

12 atom stable and uncharged ether hydrophilic linkage

Bead geometry & size

Spherical 50 to 150 um

Bead mean diameter d50v

90 um 

Linear flow velocity

<75 cm/h at 25 °C, HR 16/10 column, 5 cm bed height 

Recommended linear flow rate

<30 cm/h

Pressure/flow specification

Base matrix 100-200 cm/h, pressure drop cm H2O/bed height = 15, bed height 10 cm, 5 cm i.d. 

1ml Cartridge bed dimensions

7×25 mm

1ml Cartridge bed height

25 mm 

1ml Cartridge bed volume

1 ml 

1ml Cartridge column I.D

7 mm

5ml Cartridge bed dimensions

16×25 mm

5ml Cartridge bed height 

25 mm

5ml Cartridge bed volume 

5 ml 

5ml Cartridge column I.D

16 mm

Maximum cartridge flow rate

5 ml/min (1 ml cartridge) or 20 ml/min (5ml cartridge) 

Recommended cartridge flow rate  

1 ml/min (1 ml cartridge) or 5 ml/min (5 ml cartridge)

Maximum pressure during operation

5 bar [0.5 MPa] (70 psi)

pH Stability working range

3 to 13 

pH Stability cleaning in place (cip)

2 to 14

Chemical stability

Stable to commonly used aqueous solutions. Can be used with non-ionic detergents, denaturing solvents, e.g. 8 M urea and 6 M guanidine hydrochloride, Stable in organic solvents, e.g. 50% methylformamide and 50% dioxane.

Storage

2 to 8 °C